3. Installation
RuggedCom® RuggedSwitch® 21 RSG2300 Installation Guide Rev 110
Figure 3.21. Failsafe Alarm Relay Wiring
3.2.6. Console Port Wiring
An RS232 console port for configuration and management of the device is located on the LED
display module shown in Figure 3.22, “Console Port on Display Board”. This port is intended to
be a temporary connection during initial configuration or troubleshooting and allows direct serial
access to the management console. The connection is made using the DB9-Female to RJ45
console cable included in the device packaging shown in Figure 3.23, “RS2000 Series Console
Cable”. Console connection settings are: 57600 bps, no parity bits, 8 data bits, and 1 stop bit.
Figure 3.22. Console Port on Display Board
Figure 3.23. RS2000 Series Console Cable
Signal Name (PC is DTE) DB9- Female RJ45 Male
DCD – Carrier detect 1 2
RxD – Receive data (to DTE) 2 5
TxD – Transmit data (from DTE) 3 6
DTR – Data terminal ready 4 3
GND - Signal ground 5 4
DSR – Data set ready 6 1*
RTS – Ready to send 7 8
CTS – Clear to send 8 7