compression plate allowing either bare wire connections or crimped terminal lugs. We
recommend the use of #6 size ring lugs to ensure secure, reliable connections under
severe shock or vibration. Both terminal blocks have a safety cover which must be
removed via two Phillips screws before connecting any wires. The safety cover must be
re-attached after wiring to ensure personnel safety. Refer to Table 3 and Table 4 below
for a description of each terminal as well as sections 2.2.1 through 2.2.3 for wiring
examples.
Terminal # Description Usage
1
PS1 Live / +
is connected to the positive (+) terminal
if the power source is DC or to the (Live) terminal if
the power source is AC.
2
PS1 Surge
Ground
is connected to the Chassis
Ground via a jumper on the terminal block. Surge
Ground is used as the ground conductor for all surge
and transient suppression circuitry.
3 PS1 Neutral / -
is connected to the negative (-)
terminal if the power source is DC or to the (Neutral)
terminal if the power source is AC.
4 Chassis Ground
is connected to the Safety Ground
terminal for AC inputs or the equipment ground bus
for DC inputs. Chassis ground connects to both power
supply surge grounds via a removable jumper.
5 PS2 Live / +
is connected to the positive (+) terminal
if the power source is DC or to the (Live) terminal if
the power source is AC.
6
PS2 Surge
Ground
is connected to the Chassis
Ground via a jumper on the terminal block. Surge
Ground is used as the ground conductor for all surge
and transient suppression circuitry.
7 PS2 Neutral / -
is connected to the negative (-)
terminal if the power source is DC or to the (Neutral)
terminal if the power source is AC.
8
Relay NO
Contact
Normally open, failsafe relay contact.
9 Relay Common Failsafe relay common contact.
10 Relay NC Contact Normally closed, failsafe relay contact.
Table 3: RS416 Power terminal block connection description
Terminal Description Usage
5 PS2+
is connected to the positive (+) terminal of a
48VDC power supply
7 PS2-
is connected to the negative (-) terminal of a
48VDC power supply
Table 4: RS416/RS416P power supply connection differences